SPN 3489 — Aftertreatment 1 Air Supply Enable Actuator

Safe to driveDrivable, but watch it yourself

J1939 code SPN 3489. Below — how the fault is worded at the factory by DAF and Dongfeng, and what the second half of the code (FMI) means in the standard.

DAF

FMI 3EAS dosing module B494 air supply valve short to power supply at dosing module pin B35 (extended period)
FMI 4EAS dosing module B494 air supply valve short to ground/interruption at dosing module pin B35 or B36 (extended period)
FMI 18EAS dosing module B494 air supply valve no air supply during dosing (extended period)

Dongfeng

FMI 3Short circuit to ground of the dosing module air solenoid valve
FMI 4Short circuit to power or open circuit of the air solenoid valve

What FMI means in J1939

SPN 3489 FMI 33489/3 · 3489.3voltage above normal or shorted high
SPN 3489 FMI 43489/4 · 3489.4voltage below normal or shorted to ground
SPN 3489 FMI 183489/18 · 3489.18below normal — moderate severity

Can I keep driving

Safe to drive. Below — how much time you have and what happens if you keep going.

What happens if you keep driving

Time you have: Drivable, but watch it yourself

This is an electrical fault: an open, a short or a bad contact in the sensor circuit. The value it measures is most likely fine.

You can drive. But until the circuit is repaired this system runs blind and cannot warn you about a real failure.