← code lookup·All fault codes

SPN 4044 — Transfer Case High Range Actuator

Safe to driveTo the nearest safe stop

J1939 code SPN 4044. Below — how the fault is worded at the factory by Ford Trucks, International, Knorr-Bremse EBS and MAN, and what the second half of the code (FMI) means in the standard.

Ford TrucksInternationalKnorr-Bremse EBSMAN

Ford Trucks

Ford Trucks/Ecotorq writes fault numbers in its own format: the code in the table below is a Ford code (hexadecimal, zero-padded), not a J1939 SPN. It matches the standard only where the signal itself is standard, and usually matches the title of this page by digit alone.

FMI 11Brake pressure sensor 1 short circuit. FODP code (scan tool): C0044.
FMI 13Brake pressure sensor 1 open circuit. FODP code (scan tool): C0044.

International

FMI 5Transfer Case High Range Actuator — Transfer Case High Range Solenoid Under Current Or Open Circuit
FMI 6Transfer Case High Range Actuator — Transfer Case High Range Solenoid Short To Ground

Knorr-Bremse EBS

FMI 8Central control unit, EEPROM checksum error site ID. Wrong signal

MAN

FMI 8Central control unit EEPROM site identification - Wrong signal

What FMI means in J1939

SPN 4044 FMI 54044/5 · 4044.5current below normal or open circuit
SPN 4044 FMI 64044/6 · 4044.6current above normal or grounded circuit
SPN 4044 FMI 84044/8 · 4044.8abnormal frequency or pulse width
SPN 4044 FMI 114044/11 · 4044.11root cause not known
SPN 4044 FMI 134044/13 · 4044.13calibration out of range

Can I keep driving

Safe to drive. Below — how much time you have and what happens if you keep going.

What happens if you keep driving

Time you have: To the nearest safe stop

The gearbox or clutch has gone into limp mode: some gears may be unavailable and an automated box may stop shifting under load.

The main risk is being left on a climb with no gear and rolling back. Do not take a loaded truck into the hills; reaching level ground and a shop is fine.

Nearby: transmission

Scanner threw several codes at once? Paste the whole list — we will show which one is the root cause and which ones simply followed.