SPN 520720 is a manufacturer number outside the standard J1939 table: different makes can put different things under it. Below — how it is worded by International, and what the second half of the code (FMI) means.
| FMI 5 | Snow Plow Light Left Forward Lighting Relay Command — Left Plow Light Relay Under Current Or Open Circuit |
| FMI 6 | Snow Plow Light Left Forward Lighting Relay Command — Left Plow Light Relay Circuit Short To Ground |
| SPN 520720 FMI 5520720/5 · 520720.5 | current below normal or open circuit |
| SPN 520720 FMI 6520720/6 · 520720.6 | current above normal or grounded circuit |
Safe to drive. Below — how much time you have and what happens if you keep going.
This is an electrical fault: an open, a short or a bad contact in the sensor circuit. The value it measures is most likely fine.
You can drive. But until the circuit is repaired this system runs blind and cannot warn you about a real failure.