← code lookup·All fault codes

SPN 2392 — Reverse Lamp and Back-Up Alarm

Safe to driveDrivable, but watch it yourself

J1939 code SPN 2392. Below — how the fault is worded at the factory by International, and what the second half of the code (FMI) means in the standard.

International

FMI 5Back Up Light and Alarm Horn — Reverse Lights Relay Under Current Or Open Circuit
FMI 6Back Up Light and Alarm Horn — Reverse Lights Relay Overcurrent

What FMI means in J1939

SPN 2392 FMI 52392/5 · 2392.5current below normal or open circuit
SPN 2392 FMI 62392/6 · 2392.6current above normal or grounded circuit

Can I keep driving

Safe to drive. Below — how much time you have and what happens if you keep going.

What happens if you keep driving

Time you have: Drivable, but watch it yourself

This is an electrical fault: an open, a short or a bad contact in the sensor circuit. The value it measures is most likely fine.

You can drive. But until the circuit is repaired this system runs blind and cannot warn you about a real failure.

Nearby: other

Scanner threw several codes at once? Paste the whole list — we will show which one is the root cause and which ones simply followed.