SPN 4076 — factory code Knorr-Bremse EBS, MAN and SITRAK

Do not driveMinutes

SPN 4076 is a manufacturer number outside the standard J1939 table: different makes can put different things under it. Below — how it is worded by Knorr-Bremse EBS, MAN and SITRAK, and what the second half of the code (FMI) means.

Knorr-Bremse EBSMANSITRAK

Knorr-Bremse EBS

FMI 0Pressure control unit, checksum error external memory. Undefined fault

MAN

FMI 0Pressure control unit external memory checksum error - Undefined fault

SITRAK

FMI 22Coolant temperature downstream above threshold 1. Scan tool code: P0115. Effect: Fan and warm-up control may misbehave.
FMI 23Coolant temperature downstream above threshold 2. Scan tool code: P0115. Effect: Fan and warm-up control may misbehave.
FMI 24Coolant temperature downstream above threshold 3. Scan tool code: P0115. Effect: Fan and warm-up control may misbehave.

What FMI means in J1939

SPN 4076 FMI 04076/0 · 4076.0data above normal range (most severe level)

Can I keep driving

Do not drive. Stop as soon as it’s safe to do so — don’t keep going.

What happens if you keep driving

Time you have: Minutes

The engine is already past its temperature limit. An aluminium head goes fast: first the geometry warps, then the gasket burns through.

Next comes a blown head gasket, a damaged head and, at worst, a cracked block. Shut it down and let it cool — never open the expansion tank cap while hot.

What to check on the spot

Let the engine cool — never open the expansion tank cap while hot. Then check the level and the hoses.

Nearby: cooling